Viking's K-202-DVA is a fully programmable dialer for by reporting failures. The K-202-DVA has two potential-free contact inputs which each can call seven to 32-digit numbers and a message being played back to 1 minute in length that is specific to that input.

Viking's K-202-DVA is a fully programmable dialer for by reporting failures. The K-202-DVA has two potential-free contact inputs which each can call seven to 32-digit numbers and a message being played back to 1 minute in length that is specific to that input. 

Messages can be recorded locally or remotely with a total recording time for both inputs of 2 minutes. The K-202-DVA has traffic state detection for normal and fast busy signal, answer call, CPC (reverse polarity) and not answer. Programming is easily done with a standard DTMF telephone. 

applications 
Security / burglary / fire alarm 
Alarm system or equipment malfunction 
Liquid level monitoring 

functions 
Non-volatile memory (no batteries required) 
Space for 32 seven-digit phone numbers per entry (fourteen 32-digit numbers total) 
2 minutes of recording time (1 minute per input) 
Programmable message repeat counter 
Programmable lap counter (numbers) 
Two programmable inputs normally open (NO) or normally closed (NC) 
Programmable call delay for remote programming and alarm polling 
Qualifier programmable timer for each entry (entry delay) 
Programmable heating timer for each input (time to reset for input to become active again) 
Traffic state detection (detection capabilities during progress of the call) 
Programmable number of transient signals 
Remote security and access codes 
Local or remote programming and record 
Compatible with RC-2A and RC-3 relay controllers 
Phone numbers can be programmed as pager numbers (no voice message) 

specifications 
Power: 230V AC / 12V DC 500mA adapter included 
Dimensions: 133mm x 91mm x 44mm (5.25 "x 3.6" x 1.75 ") 
Weight: 0.68 kg (1.5 lbs) 
Setting: 0 ° C to 32 ° C (32 ° F to 90 ° F) with 5% to 95% non-condensing humidity 
Speak Voltage: 12V DC 
choose DTMF: 120 ms on / off, 50ms on / off 
CPC Detection Time: 320 ms minimum 
Message recording time: 2 minutes (total) 
Sampling Rate: 64 K 
Input detection time: 80 ms Qualifier timer 0 
Qualifier Timer Resolution: 1 second to 18 hours 
Resume Resolution Timer: 1 second to 18 hours 